Mini-Split Sizing Calculator

A load sketch for splitting BTU across heads — not Manual J. Click any i for detail.

Jump to result

Zones

Conditioned sq ft
i
Area

All rooms the system should serve.

BTU per sq ft
i
Climate

Hot ~25, mixed ~22, mild ~18.

Heads / zones
i
Heads

Indoor units. BTU is split equally for this sketch.

Insulation
i
Insulation

Scales the load. Poor older walls vs tight new construction.

How to use this calculator

  1. Enter the total area to condition.
  2. Raise the factor in a hot climate.
  3. Set how many indoor heads you want.
  4. Compare tons (12,000 BTU) to equipment catalogs.

Results explained

Load = sq ft × factor × insulation multiplier. Headline rounds to the nearest 1,000 BTU. Multi-zone jobs are rarely even splits in the real world.

Quick reference: ductless sizes

Common single-zone outdoor units are 9, 12, 18, and 24k BTU.

ItemDetail
9k BTU~0.75 ton
12k BTU1.0 ton
18k BTU1.5 ton
24k BTU2.0 ton

Line-set length, elevation, and inverter range matter as much as BTU.

How the estimate is built

BTU = area × factor × {1.15 poor | 1.0 average | 0.9 good}. Tons = BTU / 12,000.

Example scenario

350 sq ft × 22 × 1.0 = 7,700 BTU, rounds to a 9k-class single zone on many charts.

FAQ

One outdoor, two heads?

Add the rooms’ loads; don’t just split a living-room number in half without measuring both.

Heat vs cool?

This is a cooling-oriented sketch. Cold-climate heat pumps are sized on heating load.

Install cost?

See heat pump / HVAC cost calculators.